KIP-Veröffentlichungen

Jahr 2009
Autor(en) L. Fleischmann, M. Linck, A. Burck, C. Domesle, S. Kempf, A. Pabinger, C. Pies, J.-P. Porst, H. Rotzinger, S. Schäfer, R. Weldle, A. Fleischmann, C. Enss, and G. M. Seidel
Titel Metallic Magnetic Calorimeters for X-Ray Spectroscopy
KIP-Nummer HD-KIP 09-63
KIP-Gruppe(n) F4,ECHO
Dokumentart Paper
Keywords (angezeigt) Energy measurements, superconducting quantum interference devices (SQUIDs), X-ray detectors
Quelle IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY 19-2 (2009) 63-68
Abstract (en)

An increasing number of experiments employ low-temperature radiation/particle detectors which are based on a calorimetric detection scheme and operate at temperatures below 100 mK. Metallic magnetic calorimeters use a metallic paramagnetic temperature sensor in tight thermal contact with the X-ray absorber. The magnetization of the sensor is used to monitor the temperature change of the detector upon the absorption of single photons, which is proportional to the absorbed energy. Low-noise high-bandwidth dc superconducting quantum interference devices read out the small changes in magnetization. An energy resolution of Δ EFWHM = 2.7 eV was obtained for X-ray energies up to 6 keV.

bibtex
@article{GastIEEE,
  author   = {L. Fleischmann et al.},
  title    = {Metallic Magnetic Calorimeters for X-Ray Spectroscopy},
  journal  = {IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY},
  volume   = {19},
  year     = {2009},
  pages    = {63-68}
}