TransmitEnable

A sudden busy condition of the data receiving stage can be flagged to Helix128-2 by pulling low TransmitEnable; it then stops transmitting data and starts again when TransmitEnable is pulled up (this condition is checked at the falling Rclk edge). TransmitEnable is internally pulled up to +2 V.